THE PROJECT
Screening, not diagnosis
The task
Look at a retinal photograph and decide: healthy or abnormal. A clinician then examines the flagged cases. The model does not name the disease.
Why it matters
A screening model that misses disease, or works worse on some kinds of images, can delay care for the people who need it.
What I did
Fine-tuned a ViT-B/16, evaluated it with clinical metrics, tested for bias across subgroups, and discussed the ethics.
DATASET
RFMiD: 3,200 fundus photographs
3,200
photographs
45
disease categories
79.1%
abnormal
3
camera groups
Predefined split: 1,920 train, 640 validation, 640 test
Train: 1,519 abnormal and 401 healthy. Test: 506 abnormal and 134 healthy
Camera is inferred from the original image size: a proxy, not a recorded label
METHOD
Pre-processing and model
Pre-processing
Crop black borders, pad to a square, resize to 256x256 (done once)
Training only: random crop to 224x224, flips, rotation up to 15°, brightness and contrast jitter
Validation and test: resize to 224x224 only
Class imbalance handled in the loss, not by resampling
Model
ViT-B/16, about 86 million parameters, pre-trained on ImageNet-21k then ImageNet-1k
Splits the image into 196 patches of 16x16 and uses 12 self-attention layers
One output: the probability that the photograph is abnormal
Weighted binary cross-entropy, AdamW, one-cycle schedule, mixed precision, batch size 32 on a Colab T4
METHOD
Training and tuning
Four settings, 4 epochs each, one run each. I chose 1e-5 and 0.05. The differences were small, so the choice is only weakly supported
Trained 12 epochs and saved epoch 2 (validation AUC 0.9513)
Overfitting: clean training loss fell from 0.144 to 0.035, while validation loss rose to 0.162
Threshold 0.1011 chosen on the validation set, fixed before testing
RESULTS
Test set: 640 photographs
0.970
AUC
91.5%
sensitivity (463 of 506 abnormal found)
91.8%
specificity (123 of 134 healthy cleared)
Accuracy alone would mislead: 79% of the photographs are abnormal. Missing an abnormal photograph is the more serious error.
BIAS ANALYSIS
Performance depends on the camera
Sensitivity ranges from 24% to 96% across cameras, hidden by the overall 91.5%
The smallest group has only 30% abnormal in training: consistent with, but not proof of, a camera shortcut
Small sample (21 abnormal photographs), wide confidence intervals: it needs a camera-balanced experiment
BIAS ANALYSIS
Other subgroups and the threshold
Brightness and contrast
No clear bias: the confidence intervals overlap. One group has only one healthy photograph, so its specificity cannot be read.
Disease
Lowest sensitivity: ODE 70.6% (n = 17), CSR 76.9% (n = 13), ERM 80.0% (n = 5). ODC, DN, ODE and CSR account for 29 of the 43 misses.
Disease rarity
Detection is similar for rare and common diseases: 91.1%, 90.9% and 91.8%. Rarity does not explain the misses.
Threshold trade-off
Threshold 0.0570: sensitivity 0.945, specificity 0.851. 28 missed and 20 healthy flagged, against 43 and 11 at 0.1011.
EXPLAINABILITY
Attention maps are not a reliable explanation
Attention rollout combines the self-attention maps from all 12 layers into one map
Many maps show strong spots in the black corners, outside the retina. Photo 124 (probability 0.99) attends to a corner, not the lesion
The optic disc stands out in healthy and abnormal photographs. Only some true positives attend to a visible lesion
The four missed cases I examined had probabilities of 0.02 to 0.06 and looked like healthy maps
A visualisation, not proof that the model looks at the right place.
ETHICS
Ethical and societal implications
Missed disease
43 of 506 abnormal photographs missed (8.5%), including 16 of 21 in one camera group.
Unequal devices
A patient screened with an uncommon camera could get worse care unnoticed.
Fairness untested
No age, sex or ethnicity labels, and data from one country.
Over-trust
Convincing but unreliable heatmaps could encourage automation bias.
Human oversight
A trained professional makes the final decision. This is not a medical device.
Privacy and consent
RFMiD is de-identified. Real use would need consent and secure storage.
WRAP-UP
Conclusion, limits and next steps
Conclusion
The ViT separates healthy from abnormal photographs well (AUC 0.970), but sensitivity ranges from 24% to 96% by camera. A high overall score can make a model look safe. Subgroup reporting shows where it fails.
Limits
One dataset, split and seed; no external validation
Camera type is inferred; some subgroups are small
Probabilities are uncalibrated; attention rollout is unreliable
Next
External validation, camera-balanced training, multi-label disease classification
DEMO
Live demo
Open the Streamlit app and upload a test photograph
The app shows the probability of abnormal and the decision at threshold 0.101
It only says healthy or abnormal. It does not name a disease
Research prototype, not a medical device. Thank you. Questions?