Engine Start Faults
In the event of an engine start, your actions are to:
- Monitor the systems
The FADEC will take care of aborting an engine start
The FADEC will attempt to restart the engine automatically
- One cycle: A standard automatic start that includes up to three start attempts
- For ground starts: a 20 second pause is required between successive cycles
- After four failed cycles: 15 min cooling period is required