Verborgen dia's uit versie 5.0.0

Chapter 8

Attaching loads

1 / 14
volgende
Slide 1: Slide
newEditor

In deze les zitten 14 slides, met tekstslides.

Dit is niet oké

Onderdelen in deze les

Chapter 8

Attaching loads

  • What is the force in and ?


COG

S1

S2

S1

S2

S1

= (G x L2) : (L1 + L2)

= (200 x 6) : (2 + 6)

= 150 ton

S2

= (G x L1) : (L1 + L2)


= (200 x 2) : (2 + 6)

= 50 ton

150T

50T


2000 6000





What should be the length of the slings?


Angles of equipment

length: 20 ft = 6 m

width: 8 ft = 2,4 m

equipment:
four-legged sling

! External angle maximum 45° top angle maximum 90°!

relationship angles - length of the slings

What should be the length of the slings?

1. Calculate diagonal AC or BD



AB = 20 ft = 6 m

BC = 8 ft = 2,4 m

D

A

B

C

E

AC = 6,46 m

E

A

B

2. Calculate length of sling with AE

  • slings with an excluded angle of 45°:

  • AC = 6,46 : 1,4 = 4,63 m

AC = 6,46 m

C

  • 6² + 2,4² = AC²  36 + 5,76 = 41,76


  • AC = 6,46 m


45º

length of the slings: 4,63 m

Chapter 12

Safety

appendix 1:

  • art.7.18b for use of personnel baskets

  • art.7.23d for use of personnel baskets

  • new generation personnel baskets: the “FROG”



Personnel baskets

Chapter 13


Containers

Examples of incorrect packaging

Examples of incorrect packing

twist-lock on top of tank


Examples of potential ‘dropped objects’

nut in forklift pocket

wooden beam not secured

wrench on top of CCU

debris- stones in forklift pocket

hammer in CCU

  • As per below table the Periodic inspection for offshore containers and the corresponding lifting equipment according to the various production standards.


Inspection plates of containers


Inspection of containers

Inspection of containers


GENERAL CARGO CHECKLIST


Sender

Destination (operator + location)

Date Inspector

Remarks:

Signature

Marine Transport Operations - Annex I Safety Guidelines & Logistics Instructions 2020

01-10-2020

Chapter 6

Fabric slings

Working load limit flat double slings + sling assemblies

Utilisation factor





External angles >60º are forbidden