GCSE Combined Science Biology 2: Microscopy and Magnification

A Q A C O M B I N E D S C I E N C E · B I O L O G Y

Microscopy and Magnification

Topic 1 Cell biology · Lesson 2

1 / 29
volgende
Slide 1: Slide
newEditorBiologyUpper Secondary (Key Stage 4)GCSE

In deze les zitten 29 slides, met interactieve quizzen en tekstslides.

Dit is niet oké

Introductie

Students learn the parts of a light microscope, how to prepare and view a slide in Required Practical 1, and how to calculate total magnification, magnification and real size. They compare light and electron microscopes and explain why resolution limits what a light microscope can show. Foundation slides come first, followed by Higher slides on converting between mm, µm and nm and using standard form. Written for AQA GCSE Combined Science Trilogy (4.1.1.5), with a spec check for Edexcel, OCR Gateway and CCEA Double Award. This lesson was created with AI assistance.

Onderdelen in deze les

A Q A C O M B I N E D S C I E N C E · B I O L O G Y

Microscopy and Magnification

Topic 1 Cell biology · Lesson 2

Biology Lesson 2 of the GCSE Combined Science series. Written for AQA Combined Science Trilogy 8464, section 4.1.1.5 (Microscopy) and Required Practical 1 (using a light microscope to observe, draw and label plant and animal cells, with a magnification scale), Biology Paper 1.

Structure: 01 Hook, 02 Learn, 03 Check (including the Professor), 04 Go Higher (pink HIGHER badge), 05 Apply and Review. Foundation groups can stop before section 04.

Every question is taught on the slide just before it, and the calculations are followed by an "answers explained" slide. Students need calculators. If you have microscopes, slides 8 and 9 can be done as the practical.

0 1 / H O O K

Which of these could you see with a school microscope?

1

A cell's nucleus

2

A ribosome

3

A virus

4

All three

B I O L O G Y

Take a vote and use the spinner to hear a few reasons.

Only the nucleus. Ribosomes and viruses are far too small for a light microscope - you need an electron microscope. The next slide reveals this, and the reason (resolution) comes later in the lesson.

0 1 / H O O K

Only the nucleus!

A school light microscope can show you cells and their nucleus.

Ribosomes and viruses are much too small. To see them, scientists use an electron microscope.

Today you will learn to use a microscope, work out magnification - and find out why some things stay invisible.

B I O L O G Y

Link back to the vote. Keep the ribosome in mind - the Professor makes a mistake about it later.

T O D A Y ' S G O A L S

By the end of the lesson

Foundation

  • I can name the parts of a light microscope and prepare a slide.

  • I can calculate total magnification, magnification and real size.

  • I can compare light and electron microscopes, using the word resolution.

Higher

  • I can convert between mm, µm and nm, and use standard form.

B I O L O G Y

Share the goals. Foundation goals are for everyone; the Higher goal is covered in section 04.

0 2 / L E A R N

The light microscope

The eyepiece and objective lenses magnify the specimen.

The slide sits on the stage, with light shining up through it.

Coarse focus makes big moves; fine focus sharpens the image.

B I O L O G Y

Most school microscopes have three objective lenses, usually ×4, ×10 and ×40, and a ×10 eyepiece.

If you have microscopes, let students find each part on a real one.

0 2 / L E A R N

Total magnification

A light microscope has two lenses, and each one magnifies.

To find the total magnification, multiply them:

total magnification = eyepiece lens × objective lens

Worked example: a ×10 eyepiece and a ×40 objective.

10 × 40 = ×400

The image looks 400 times bigger than the real specimen.

B I O L O G Y

Teaches the method for the next question. Common error - adding the two numbers (10 + 40 = 50).

0 3 / C H E C K

The eyepiece lens is ×10 and the objective lens is ×10. What is the total magnification?

A

×20

B

×1

C

×1000

D

×100

Answer: ×100. 10 × 10 = 100. ×20 means the student added the lenses.

R E Q U I R E D P R A C T I C A L 1

Making a slide

  1. Peel a thin layer of onion skin with forceps - thin enough for light to pass through.

  2. Lay it flat on a drop of water on a microscope slide.

  3. Add a drop of iodine solution. This stains the cells so the nucleus and cell wall show up.

  4. Lower a cover slip at an angle using a mounted needle. Lowering it slowly at an angle stops air bubbles getting trapped. The cover slip also keeps the specimen flat.

B I O L O G Y

AQA Required Practical 1. Iodine solution can stain skin and clothes - students should take care. Cheek cells (stained with methylene blue) are an alternative animal specimen, following your school's risk assessment.

The reasons in bold are what exam questions usually ask for.

R E Q U I R E D P R A C T I C A L 1

Viewing and drawing

  1. Put the slide on the stage and select the lowest-power objective - it gives the widest view, so the cells are easiest to find.

  2. Use the coarse focus to bring the lens close to the slide, then move it away until the cells come into focus.

  3. Sharpen with the fine focus, then switch to a higher-power lens and refocus with the fine focus.

  4. Draw in pencil, with clear lines and no shading. Label with ruled lines, and write the magnification.

B I O L O G Y

Watching from the side while moving the lens towards the slide stops it crashing into the slide. Scientific drawings show what you actually see, not a textbook picture.

0 3 / C H E C K

Why is the cover slip lowered slowly, at an angle?

A

To stain the cells

B

To stop air bubbles

C

To magnify the cells

D

To let more light through

Answer: to stop air bubbles being trapped. Air bubbles look like dark-edged circles and hide the cells. Staining is the job of the iodine. Image credit: Logan Gutierrez / Unsplash

0 2 / L E A R N

Calculating magnification

magnification = image size ÷ real size

Image size is how big it looks in a drawing or photo. Real size is how big the specimen really is.

Both sizes must be in the same unit, such as mm.

Worked example: a drawing of a cell is 20 mm long. The real cell is 0.1 mm long.

magnification = 20 ÷ 0.1 = ×200

Magnification has no unit - just write ×.

B I O L O G Y

AQA 4.1.1.5. Students must be able to use this equation and rearrange it. Some students find a formula triangle helpful: image on top, real and magnification underneath.

Check: the magnification should be bigger than 1 when the image is bigger than the real thing.

0 3 / C H E C K

A drawing of a cell is 50 mm long. The real cell is 0.5 mm long. What is the magnification?

A

×25

B

×100

C

×0.01

D

×1000

Answer: ×100. 50 ÷ 0.5 = 100. ×0.01 divides the wrong way round; ×25 multiplies.

0 2 / L E A R N

Finding the real size

Rearrange the equation: real size = image size ÷ magnification

Cells are tiny, so we often use micrometres (µm). 1 mm = 1000 µm

Worked example: an image of a cell is 15 mm long at ×300.

real size = 15 ÷ 300 = 0.05 mm

In micrometres: 0.05 × 1000 = 50 µm

Check: the real size must be smaller than the image.

B I O L O G Y

Teaches the rearrangement for the next question. To change mm to µm, multiply by 1000.

0 3 / C H E C K

An image of a cell is 20 mm wide at ×400. What is the real width of the cell?

A

8000 mm

B

5 mm

C

0.05 mm

D

0.5 mm

Answer: 0.05 mm. 20 ÷ 400 = 0.05 mm (50 µm). 8000 mm multiplies instead of divides.

T H E A N S W E R S E X P L A I N E D

How did we get those?

Magnification: image ÷ real = 50 ÷ 0.5 = ×100. The image is bigger, so the answer must be bigger than 1.

Real size: image ÷ magnification = 20 ÷ 400 = 0.05 mm, which is 50 µm.

Got 8000 mm? You multiplied. A real cell can't be 8 metres wide - always check your answer makes sense.

B I O L O G Y

Go through both answers after the class has voted. Ask students to say out loud which number goes on top each time.

0 2 / L E A R N

Light vs electron microscopes

Resolution is the ability to tell apart two points that are close together. Higher resolution gives a sharper, more detailed image.

Light microscope: uses light · magnifies up to about ×2000 · resolution about 200 nm · can view living cells · cheap, so used in school labs. Shows cells, the nucleus, chloroplasts and the cell wall.

Electron microscope: uses a beam of electrons · magnifies up to about ×2 000 000 · much higher resolution, under 1 nm. Shows much smaller things - ribosomes, plasmids and detail inside mitochondria and chloroplasts.

B I O L O G Y

AQA 4.1.1.5. Electron microscopes have much higher magnification and resolving power, so they let scientists see subcellular structures in far more detail. They are expensive and large, and specimens are viewed in a vacuum, so living cells cannot be viewed.

1 nm (nanometre) is a millionth of a millimetre. Higher students convert between units in section 04.


Light or electron microscope? Drag each feature

LIGHT MICROSCOPE

ELECTRON MICROSCOPE

Uses a beam of electrons

Used in school labs

Magnifies up to about ×2000

Can view living cells

Can show ribosomes

Shows detail inside mitochondria

B I O L O G Y

Light microscope: used in school labs; magnifies up to about ×2000; can view living cells. Electron microscope: uses a beam of electrons; can show ribosomes; shows detail inside mitochondria.

Follow-up: which one has the higher resolution? (Electron.)

0 3 / C H E C K

"If I keep turning up the magnification on my light microscope, I'll be able to see the ribosomes!" Is the Professor right? Explain.

T H E P R O F E S S O R S A Y S . . .

B I O L O G Y

The Professor's misconception, as an open question - students type their answers. The animation zooms in from ×400 to ×6000: the image gets bigger, but the ribosome only gets blurrier.

He is wrong: magnifying more does not add detail. A light microscope's resolution is about 200 nm, so it cannot separate details smaller than that. Ribosomes are only about 20-30 nm across, so they stay a blur however much the image is magnified. He needs an electron microscope, which has a much higher resolution.

Look for: "resolution", "too small", "blurry", "electron microscope".

T H E A N S W E R E X P L A I N E D

Sorry, Professor!

Making the image bigger doesn't add detail. Past a point, it just gets bigger and blurrier.

A light microscope's resolution is about 200 nm - it can't tell apart details closer than that. Ribosomes are only about 20-30 nm across.

To see ribosomes you need an electron microscope, which has a much higher resolution.

B I O L O G Y

Go through this after students have typed their answers. Ask someone who used the word "resolution" to explain it before revealing this slide.

Microscopes recap

Electron microscopes have a much higher magnification and resolution than light microscopes. Resolution is the ability to tell apart two points that are close together. Ribosomes are too small to see with a light microscope. To see them, you need an electron microscope.

magnification
resolution
close
small
electron
light
big
colour
far

B I O L O G Y

A recap of the last four slides. The distractor "light" tests the Professor's misconception.

S P E C C H E C K

Your exam spec

Microscopes, magnification and a microscopy practical are in every specification.

AQA Combined Science Trilogy (8464) - 4.1.1.5 Microscopy and Required Practical 1, Biology Paper 1.

Edexcel Combined Science (1SC0) - Topic 1 Key concepts in biology, including the core practical on using microscopes and magnification.

OCR Gateway Combined Science (J250) - B1 Cell level systems, including microscopy.

CCEA Double Award Science (NI) - Biology, cells, including the prescribed practical on preparing and viewing slides.

B I O L O G Y

A variant slide for classes on other specifications. The core content is shared, but topic numbers, practical names and the units used can differ - check your specification before teaching.

Delete this slide if your class only sits AQA.

0 4 / G O H I G H E R

Tiny units and standard form

1 m = 1000 mm · 1 mm = 1000 µm · 1 µm = 1000 nm

To a smaller unit, multiply by 1000. To a bigger unit, divide by 1000.

Worked example: a ribosome image is 5 mm wide at ×200 000.

real size = 5 ÷ 200 000 = 0.000025 mm → × 1000 = 0.025 µm → × 1000 = 25 nm

In standard form: 0.000025 mm = 2.5 × 10-5 mm

B I O L O G Y

HIGHER

Higher slide. Teaches the unit conversions and standard form needed for the next two questions and the Higher exam question.

Standard form: count how many places the decimal point moves to the right to make a number between 1 and 10 - that is the negative power. (Students met this in Lesson 1.)

0 4 / G O H I G H E R

A mitochondrion's image is 30 mm long at ×15 000. What is its real length?

HIGHER

A

0.2 µm

B

2 µm

C

20 µm

D

450 000 µm

Answer: 2 µm. 30 ÷ 15 000 = 0.002 mm, × 1000 = 2 µm. 450 000 µm multiplies instead of divides.

0 4 / G O H I G H E R

A light microscope's resolution is about 200 nm. What is this in µm?

HIGHER

A

2 µm

B

200 000 µm

C

0.02 µm

D

0.2 µm

Answer: 0.2 µm. µm is the bigger unit, so divide by 1000: 200 ÷ 1000 = 0.2 µm. 200 000 µm multiplies instead. Image credit: Bioscience Image Library by Fayette Reynolds / Unsplash

T H E A N S W E R S E X P L A I N E D

How did we get those?

Mitochondrion: real size = 30 ÷ 15 000 = 0.002 mm. To µm (smaller unit), multiply by 1000: 2 µm.

Resolution: nm → µm is going to a bigger unit, so divide by 1000: 200 ÷ 1000 = 0.2 µm.

Tip: a smaller unit means a bigger number. 0.2 µm and 200 nm are the same length.

B I O L O G Y

HIGHER

Talk through both Higher answers. Ask students to say "smaller unit, bigger number" before each conversion.

0 5 / A P P L Y & R E V I E W

Exam practice

Question

A student draws an onion cell. The drawing is 40 mm long. The real cell is 0.2 mm long.

Calculate the magnification of the drawing. [2 marks]

Working space

Model answer

Key takeaway

Magnification = image size ÷ real size. Use the same units for both.

B I O L O G Y

FOUNDATION

Foundation exam question. One mark for correct substitution, one for the answer.

0 5 / A P P L Y & R E V I E W

Exam practice

Question

A micrograph of a bacterium is 40 mm long at ×20 000.

Calculate its real length in metres, in standard form. [3 marks]

Working space

Model answer

Key takeaway

Find the real size first, then change the unit, then write it in standard form.

B I O L O G Y

HIGHER

Higher exam question. Allow the third mark for a correct standard form answer carried forward from an earlier slip.

These are model points in the style of an AQA mark scheme, not an official mark scheme.

0 5 / A P P L Y & R E V I E W

Exit ticket: what can an electron microscope show that a light one can't? Why?

B I O L O G Y

Exit ticket. Good answers: ribosomes, plasmids or detail inside mitochondria/chloroplasts, because the electron microscope has a much higher resolution (and magnification), so it can tell apart details far smaller than 200 nm.

Great work, scientists!

Next biology lesson - Biology 3, Cell specialisation and differentiation.